/****************************************/ /* EZ Data Logger */ /* For DCON modules 7k/87k/8k */ /* For Modbus RTU modules M-7000 */ /* since 2006/06/02 */ /****************************************/ ================================================================================ Version:4.1.0 [2008/08/15] by Mac New device supported DI/DO function of PDS-700 series. Since version 4.1.0, a license key is required. There are two kinds of license keys. 1.Basic Edition License Key: A basic edition license key is required to unlock the 2 hours execution time limitation. The basic edition is free. You have to enter some personal data(Company, Name, Country, Email) to get a key from our registration web page. 2.Professional Edition License Key: You must pay for the license of the software. Once you purchase the software, you will get a product serial number. Then you have to link to the registration web page and enter a. product serial number b. PC ID code to get a license key. To get the PC ID Code the EZ Data Logger has to be installed on your PC. Click on the "About" button of the EZ Data Logger program main tool bar to display the PC ID Code. Each product serial number allows you to register up to 3 PCs. Registration web page: http://www.icpdas.com/products/Software/ez_data_logger/ez_data_logger.html Versions comparison Features Basic Edition Professional Edition Time Limit No No Virtual Channel Number 32 256 Control Logic Enabled Enabled Web Camera Number 1 10 Alarm contact to(email or SMS) 2 10 IO Tag Number 64 1024 ================================================================================ Version:4.0.0 [2008/07/11] by Mac New features 1.Alarm Notification: There is a new program called "SMS & Mail Sender" handling the E-mail and SMS sending. It was minimum sized at the system tray. The SMS & Mail Sender will send alarm messages by E-mail or SMS when AI value a. over high alarm b. under low alarm c. back to normal The alarm messages are also logged to the database. When opening the database, you can see the alarm messages. 2.IP Camera Viewer: User can add an IP camera's web address, and then add it to group. Then the layout display will show the web page in a sub window. New driver supported 1. Mail Notifier Driver You can set it's SMTP server and give a head text. This driver works for E-mail sending. No other devices need to be added. 2. GSM Modem Driver You can add a GSM modem device and give a head text. This driver works for SMS sending. The GSM modem must support PDU mode, that is to say, AT command "AT+CMGF=0" can work on it. New device supported 1. Contact list Contact list is used for defining mail address of mail notification and cell phone number of SMS notification. 2. IP Camera You can add IP camera's web address directly in the Web Camera List. It was shown by an IE sub window in layout display. Bug Fix: The modbus outputs do not work correctly in Control Logic. Modify: User can delete a single channel in workgroup by mouse right click. ================================================================================ Version:3.0.2 [2008/6/4] by Mac Fix Bug: Modbus communication sometimes does not work with 8xx7 ISaGRAF based PAC. Add single channel scale setting in layout. ================================================================================ Version:3.0.1 [2008/5/16] by Mac Fix Bug: When you installed an earlier version of EZ Data Logger in your computer, the Modbus communication does not work in v3.0.0. ================================================================================ Version:3.0.0 [2008/4/15] by Mac Support DCON Frequency/Counter Modules:I-7080, I-7081, I-7083, I-8080, I-8081, I-87082. Support DCON DI Counter. Support Modbus data format : Long / Float / Double and the Inverse. Support Visual Channel definition. User can operate the data into the visual channel by channel tag names easily. For example: VC1 = (AI_1 + AI_2) / 2 Support Control Logic. User can edit the script to set the output values or to caculate data into visual channels. You can get/set the channel values by channel tag names. For example : If AI0 > 50 Then DO0=1 Support 7 kinds of layout object. Include : Text Box, Angular Gauge, Linear Gauge, Percent, Number LED, Toggle, Odometer. And you can choose styles. ================================================================================ Version:2.0.9 [2007/07/31] by Mac Support I-7000 series modules that with only one analog input channel: I-7011, I-7012, I-7013, I-7014. Support "Wire Opening Detection" for AI modules with DCON protocol : Some DCON analog input modules (for Thermocouple, Thermistor, and RTD input) support "Wire Open Detection", such as I-7005, I-7018BL, I-7018R, I-7018Z, I-7019R, I-7013, I-7033, I-7015, I-87013, I-87018, I-87018Z. When wire opening is detected, the value becomes "+9999.9", "0" or "-9999.9". And EZ Data Logger will active the High/Low alarm and show "over range" message at the moment. Fix Bug: In Germany value format, Gain and Offset are not transfered correctly. ================================================================================ Version:2.0.7 [2007/05/04] by Mac Support DCON / Modbus serial / Modbus TCP protocol Support miltiple COM Port / TCPIP connections Trend(1 analog, 2 digital) Support I-7000, I-87K, I-8000, M-7000 serial searching Support configuration file export/import Support password protection Change default install directory to c:\program file\ICPDAS\EZ Data Logger ================================================================================ Version:1.1.2 [2006/09/27] by Mac Fix bug:When export data to excel, the last data does not export. Add language:Simple Chinese Add cursor on trend line of the opendata form. ================================================================================ Version:1.1.1 [2006/09/27] by Mac Fix bug: 1.Change to a COM Port that is not exist return an error code, and the error code is not reset when user set back to a correct COM Port. 2.When runs on windows98, the menu are null.(language file format problem) ================================================================================ Version:1.1.0 [2006/09/19] by Mac Support DCON modules(DI/DO, AI/AO) Support digital trend line.(1 analog, 3 digital) Add module status Add layout display 1.Can change to user design back picture. 2.Can drag and drop IO points in Drag/Drop mode. 3.Can change to user design digital on/off picture. Modify: 1.Each channel can be assigned to any workgroup 2.Can import *.map module configuration file from DCON utility 3.Continuously record time that user can set more than 24 hours to log data V1.0.7=>change to a new log database when 12:00 pm. V1.1.0=>change to a new log database when record time is up. 4.Can modify a batch of channels's description, gain, offset, and alarm limit. Disable show CJC. ================================================================================ Version:1.0.7 [2006/06/29] by Mac Add Gain,Offset Fix bug: build database error(Selected Collating Sequence Not Supported) ================================================================================ Version:1.0.6 [2006/06/06] by Mac Fix SQL error(open recordset by scroll graph X bar ,Date format=>Cdbl(date)) Fix bug(channel check box loaded ok or not, to refresh ADODC or not) Fix bug(Install directory) Fix bug(Export Null when Export twice) ================================================================================ Version:1.0.5 [2006/06/06] by Mac Add CJC value show on scope,database can be checked to show or not Modify scope stracks to be one all trend lines put together. CJC trend lines show on another track Add .cvs format export Modify AI module number limit to 5 in a workgroup(Add scroll bar to show channels) ================================================================================ Version:1.0.4 [2006/06/02] by Mac New function simulation:Random value for simulation autoColor:auto color for module added New form frmCommomDialog:for commondialog position Change direct error.txt and logfile(*.mdb) saved in subdirect "\log\" Add readme file:EZDataLog.pdf